logo

Serinus Cal 3000

The Serinus Cal 3000 is an advanced multi-gas dilution calibrator with an integrated ozone generator and photometer. It is designed for precise creation and delivery of ozone concentrations, providing a reliable transfer standard for calibrating ozone analyzers. The instrument is suitable for environmental applications and supports calibration of gases such as CO, CO₂, O₃, NOx, NOy, NH₃, and SO₂.

Serinus Cal 3000

Specification

Dilution & Flow

  • Dilution Gas Inputs: 1 standard 100–200 kPa (2 optional)

  • Source Gas Inputs: 4 standard 100–200 kPa (8 optional)

  • Dilution Mass Flow Controller: 10 SLPM (standard), optional 1, 2, 5, 20 SLPM

  • Source Mass Flow Controller: 50 SCCM (standard), optional 10 SCCM–1 SLPM

  • Flow Accuracy: Within 1% of full scale

  • Flow Repeatability: Within 0.15% of full scale

  • Linearity: Within 0.15% of full scale

  • Operating Gas Pressure: 100–200 kPa

  • Response Time: < 5 seconds

  • Output Manifold: 4 ports standard

  • Dilution Ratio: Variable 10:1 to 2000:1

Dimensions & Weight

  • Rack Length: 597 mm (23.5”)

  • Total Length: 638 mm (25.1”)

  • Chassis Width: 418 mm (16.5”)

  • Front Panel Width: 429 mm (16.9”)

  • Chassis Height: 163 mm (6.4”, 4RU)

  • Front Panel Height: 175 mm (6.9”)

  • Weight: 23.8 kg

Power & Operating Conditions

  • Operating Voltage: 100–240 VAC, 50/60 Hz (autoranging)

  • Power Consumption: 165 VA max at start-up, 95 VA after warm-up

  • Temperature Range: 0–45 °C (optimal 20–35 °C)

  • Maximum Altitude: 3000 m

Ozone Generator & Photometer

  • Ozone Output: 3 ppb to 5000 ppb, flow variable

  • Repeatability: < 1% short term, 5% long term

  • Photometer Range: 0–20 ppm

  • Precision: 0.5 ppb or 0.2% of reading

  • Linearity: < 1% of full scale

  • Response Time: 30 seconds to 95%

  • Zero Drift: < 0.3 ppb (24h & 7 days)

  • Span Drift: 0.5% of reading over 7 days

Description

The Serinus Cal 3000 combines a dilution calibrator with an integrated ozone photometer and generator, allowing precise and continuous ozone measurements. The photometer assembly includes an optical cell, detectors, UV lamp, heater, and thermistor to maintain accurate ozone output. Its intuitive interface simplifies operation, and its reliable technology ensures long-term, trouble-free use. The calibrator provides stable zero air or gas dilutions, making it a versatile tool for laboratory and field applications in environmental monitoring.

Gallery

logo
Advanced Functional Material Laboratory
Bandung Institute of Technology
Address

Jalan Ganesh a No.10, Lebak Siliwangi, Coblong, Institut Teknologi Bandung, Lb. Siliwangi, Kecamatan Coblong, Kota Bandung, Jawa Barat 40132

© 2024 Advanced Functional Material Laboratory

Bandung, Indonesia